Subpart A--General Provisions
§ 36.1 Purpose and scope.
(a) This part contains requirements for the issuance of a license authorizing the use of sealed sources containing radioactive
materials in irradiators used to irradiate objects or materials using gamma radiation. This part also contains radiation safety
requirements for operating irradiators. The requirements of this part are in addition to other requirements of this chapter. In
particular, the provisions of parts 19, 20, 21, 30, 71, 170, and 171 of this chapter apply to applications and licenses subject
to this part. Nothing in this part relieves the licensee from complying with other applicable Federal, State and local
regulations governing the siting, zoning, land use, and building code requirements for industrial facilities.
(b) The regulations in this part apply to panoramic irradiators that have either dry or wet storage of the radioactive sealed
sources and to underwater irradiators in which both the source and the product being irradiated are under water. Irradiators
whose dose rates exceed 5 grays (500 rads) per hour at 1 meter from the radioactive sealed sources in air or in water, as
applicable for the irradiator type, are covered by this part.
(c) The regulations in this part do not apply to self-contained dry-source-storage irradiators (those in which both the source
and the area subject to irradiation are contained within a device and are not accessible by personnel), medical radiology or
teletherapy, radiography (the irradiation of materials for nondestructive testing purposes), gauging, or open-field
(agricultural) irradiations.
§ 36.2 Definitions.
Annually means either (1) at intervals not to exceed 1 year or (2) once per year, at about the same time each year (plus or
minus 1 month).
Doubly encapsulated sealed source means a sealed source in which the radioactive material is sealed within a capsule and
that capsule is sealed within another capsule.
Irradiator means a facility that uses radioactive sealed sources for the irradiation of objects or materials and in which
radiation dose rates exceeding 5 grays (500 rads) per hour exist at 1 meter from the sealed radioactive sources in air or
water, as applicable for the irradiator type, but does not include irradiators in which both the sealed source and the area
subject to irradiation are contained within a device and are not accessible to personnel.
Irradiator operator means an individual who has successfully completed the training and testing described in § 36.51 and is
authorized by the terms of the license to operate the irradiator without a supervisor present.
Panoramic dry-source-storage irradiator means an irradiator in which the irradiations occur in air in areas potentially
accessible to personnel and in which the sources are stored in shields made of solid materials. The term includes beam-type
dry-source-storage irradiators in which only a narrow beam of radiation is produced for performing irradiations.
Panoramic irradiator means an irradiator in which the irradiations are done in air in areas potentially accessible to
personnel. The term includes beam-type irradiators.
Panoramic wet-source-storage irradiator means an irradiator in which the irradiations occur in air in areas potentially
accessible to personnel and in which the sources are stored under water in a storage pool.
Pool irradiator means any irradiator at which the sources are stored or used in a pool of water including panoramic
wet-source-storage irradiators and underwater irradiators.
Product conveyor system means a system for moving the product to be irradiated to, from, and within the area where
irradiation takes place.
Radiation room means a shielded room in which irradiations take place. Underwater irradiators do not have radiation
rooms.
Radiation safety officer means an individual with responsibility for the overall radiation safety program at the facility.
Sealed source means any byproduct material that is used as a source of radiation and is encased in a capsule designed to
prevent leakage or escape of the byproduct material.
Seismic area means any area where the probability of a horizontal acceleration in rock of more than 0.3 times the
acceleration of gravity in 250 years is greater than 10 percent, as designated by the U.S. Geological Survey.
Underwater irradiator means an irradiator in which the sources always remain shielded under water and humans do not
have access to the sealed sources or the space subject to irradiation without entering the pool.
§ 36.8 Information collection requirements: OMB approval.
(a) The Nuclear Regulatory Commission has submitted the information collection requirements contained in this part to the
Office of Management and Budget (OMB) for approval as required by the Paperwork Reduction Act (44 U.S.C. 3501 et
seq.). The NRC may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it
displays a currently valid OMB control number. OMB has approved the information collection requirements contained in
this part under control number 3150-0158.
(b) The approved information collection requirements contained in this part appear in §§ 36.11, 36.13, 36.17, 36.19, 36.21,
36.53, 36.69, 36.81, and 36.83.
(c) This part contains information collection requirements in addition to those approved under the control number specified
in paragraph (a) of this section. These information collection requirements and the control numbers under which they are
approved are as follows:
(1) In § 36.11, NRC Form 313 is approved under control number 3150-0120.
(2) [Reserved]
[58 FR 7728, Feb. 9, 1993, as amended at 62 FR 52187, Oct. 6, 1997]
§ 36.13 Specific licenses for irradiators.
The Commission will approve an application for a specific license for the use of licensed material in an irradiator if the
applicant meets the requirements contained in this section.
(a) The applicant shall satisfy the general requirements specified in § 30.33 of this chapter and the requirements contained in
this part.
(b) The application must describe the training provided to irradiator operators including--
(1) Classroom training;
(2) On-the-job or simulator training;
(3) Safety reviews;
(4) Means employed by the applicant to test each operator's understanding of the Commission's regulations and licensing
requirements and the irradiator operating and emergency procedures; and
(5) Minimum training and experience of personnel who may provide training.
(c) The application must include an outline of the written operating and emergency procedures listed in § 36.53 that
describes the radiation safety aspects of the procedures.
(d) The application must describe the organizational structure for managing the irradiator, specifically the radiation safety
responsibilities and authorities of the radiation safety officer and those management personnel who have important
radiation safety responsibilities or authorities. In particular, the application must specify who, within the management
structure, has the authority to stop unsafe operations. The application must also describe the training and experience
required for the position of radiation safety officer.
(e) The application must include a description of the access control systems required by § 36.23, the radiation monitors
required by § 36.29, the method of detecting leaking sources required by § 36.59 including the sensitivity of the method, and
a diagram of the facility that shows the locations of all required interlocks and radiation monitors.
(f) If the applicant intends to perform leak testing of dry-source-storage sealed sources, the applicant shall establish
procedures for leak testing and submit a description of these procedures to the Commission. The description must include
the--
(1) Instruments to be used;
(2) Methods of performing the analysis; and
(3) Pertinent experience of the individual who analyzes the samples.
(g) If licensee personnel are to load or unload sources, the applicant shall describe the qualifications and training of the
personnel and the procedures to be used. If the applicant intends to contract for source loading or unloading at its facility,
the loading or unloading must be done by an organization specifically authorized by the Commission or an Agreement
State to load or unload irradiator sources.
(h) The applicant shall describe the inspection and maintenance checks, including the frequency of the checks required by
§ 36.61.
Subpart C--Design and Performance Requirements for Irradiators
§ 36.21 Performance criteria for sealed sources.
(a) Requirements. Sealed sources installed after July 1, 1993:
(1) Must have a certificate of registration issued under 10 CFR 32.210;
(2) Must be doubly encapsulated;
(3) Must use radioactive material that is as nondispersible as practical and that is as insoluble as practical if the source is
used in a wet-source-storage or wet-source-change irradiator;
(4) Must be encapsulated in a material resistant to general corrosion and to localized corrosion, such as 316L stainless steel
or other material with equivalent resistance if the sources are for use in irradiator pools; and
(5) In prototype testing of the sealed source, must have been leak tested and found leak-free after each of the tests described
in paragraphs (b) through (g) of this section.
(b) Temperature. The test source must be held at -40șC for 20 minutes, 600șC for 1 hour, and then be subjected to a thermal
shock test with a temperature drop from 600șC to 20șC within 15 seconds.
(c) Pressure. The test source must be twice subjected for at least 5 minutes to an external pressure (absolute) of 2 million
newtons per square meter.
(d) Impact. A 2-kilogram steel weight, 2.5 centimeters in diameter, must be dropped from a height of 1 meter onto the test
source.
(e) Vibration. The test source must be subjected 3 times for 10 minutes each to vibrations sweeping from 25 hertz to 500
hertz with a peak amplitude of 5 times the acceleration of gravity. In addition, each test source must be vibrated for 30
minutes at each resonant frequency found.
(f) Puncture. A 50-gram weight and pin, 0.3-centimeter pin diameter, must be dropped from a height of 1 meter onto the
test source.
(g) Bend. If the length of the source is more than 15 times larger than the minimum cross-sectional dimension, the test
source must be subjected to a force of 2000 newtons at its center equidistant from two support cylinders, the distance
between which is 10 times the minimum cross-sectional dimension of the source.
§ 36.23 Access control.
(a) Each entrance to a radiation room at a panoramic irradiator must have a door or other physical barrier to prevent
inadvertent entry of personnel if the sources are not in the shielded position. Product conveyor systems may serve as
barriers as long as they reliably and consistently function as a barrier. It must not be possible to move the sources out of
their shielded position if the door or barrier is open. Opening the door or barrier while the sources are exposed must cause
the sources to return promptly to their shielded position. The personnel entrance door or barrier must have a lock that is
operated by the same key used to move the sources. The doors and barriers must not prevent any individual in the radiation
room from leaving.
(b) In addition, each entrance to a radiation room at a panoramic irradiator must have an independent backup access control
to detect personnel entry while the sources are exposed. Detection of entry while the sources are exposed must cause the
sources to return to their fully shielded position and must also activate a visible and audible alarm to make the individual
entering the room aware of the hazard. The alarm must also alert at least one other individual who is onsite of the entry.
That individual shall be trained on how to respond to the alarm and prepared to promptly render or summon assistance.
(c) A radiation monitor must be provided to detect the presence of high radiation levels in the radiation room of a
panoramic irradiator before personnel entry. The monitor must be integrated with personnel access door locks to prevent
room access when radiation levels are high. Attempted personnel entry while the monitor measures high radiation levels,
must activate the alarm described in paragraph (b) of this section. The monitor may be located in the entrance (normally
referred to as the maze) but not in the direct radiation beam.
(d) Before the sources move from their shielded position in a panoramic irradiator, the source control must automatically
activate conspicuous visible and audible alarms to alert people in the radiation room that the sources will be moved from
their shielded position. The alarms must give individuals enough time to leave the room before the sources leave the
shielded position.
(e) Each radiation room at a panoramic irradiator must have a clearly visible and readily accessible control that would
allow an individual in the room to make the sources return to their fully shielded position.
(f) Each radiation room of a panoramic irradiator must contain a control that prevents the sources from moving from the
shielded position unless the control has been activated and the door or barrier to the radiation room has been closed within
a preset time after activation of the control.
(g) Each entrance to the radiation room of a panoramic irradiator and each entrance to the area within the personnel access
barrier of an underwater irradiator must be posted as required by 10 CFR 20.1902. Radiation postings for panoramic
irradiators must comply with the posting requirements of 10 CFR 20.1902, except that signs may be removed, covered, or
otherwise made inoperative when the sources are fully shielded.
(h) If the radiation room of a panoramic irradiator has roof plugs or other movable shielding, it must not be possible to
operate the irradiator unless the shielding is in its proper location. This requirement may be met by interlocks that prevent
operation if shielding is not placed properly or by an operating procedure requiring inspection of shielding before
operating.
(i) Underwater irradiators must have a personnel access barrier around the pool which must be locked to prevent access
when the irradiator is not attended. Only operators and facility management may have access to keys to the personnel
access barrier. There must be an intrusion alarm to detect unauthorized entry when the personnel access barrier is locked.
Activation of the intrusion alarm must alert an individual (not necessarily onsite) who is prepared to respond or summon
assistance.
§ 36.33 Irradiator pools.
(a) For licenses initially issued after July 1, 1993, irradiator pools must either:
(1) Have a water-tight stainless steel liner or a liner metallurgically compatible with other components in the pool; or
(2) Be constructed so that there is a low likelihood of substantial leakage and have a surface designed to facilitate
decontamination. In either case, the licensee shall have a method to safely store the sources during repairs of the pool.
(b) For licenses initially issued after July 1, 1993, irradiator pools must have no outlets more than 0.5 meter below the
normal low water level that could allow water to drain out of the pool. Pipes that have intakes more than 0.5 meter below
the normal low water level and that could act as siphons must have siphon breakers to prevent the siphoning of pool water.
(c) A means must be provided to replenish water losses from the pool.
(d) A visible indicator must be provided in a clearly visible location to indicate if the pool water level is below the normal
low water level or above the normal high water level.
(e) Irradiator pools must be equipped with a purification system designed to be capable of maintaining the water during
normal operation at a conductivity of 20 microsiemens per centimeter or less and with a clarity so that the sources can be
seen clearly.
(f) A physical barrier, such as a railing or cover, must be used around or over irradiator pools during normal operation to
prevent personnel from accidentally falling into the pool. The barrier may be removed during maintenance, inspection, and
service operations.
(g) If long-handled tools or poles are used in irradiator pools, the radiation dose rate on the handling areas of the tools may
not exceed 0.02 millisievert (2 millirems) per hour.
§ 36.39 Design requirements.
Irradiators whose construction begins after July 1, 1993, must meet the design requirements of this section.
(a) Shielding. For panoramic irradiators, the licensee shall design shielding walls to meet generally accepted building code
requirements for reinforced concrete and design the walls, wall penetrations, and entranceways to meet the radiation
shielding requirements of § 36.25. If the irradiator will use more than 2 x 1017 becquerels (5 million curies) of activity, the
licensee shall evaluate the effects of heating of the shielding walls by the irradiator sources.
(b) Foundations. For panoramic irradiators, the licensee shall design the foundation, with consideration given to soil
characteristics, to ensure it is adequate to support the weight of the facility shield walls.
(c) Pool integrity. For pool irradiators, the licensee shall design the pool to assure that it is leak resistant, that it is strong
enough to bear the weight of the pool water and shipping casks, that a dropped cask would not fall on sealed sources, that
all outlets or pipes meet the requirements of § 36.33(b), and that metal components are metallurgically compatible with
other components in the pool.
(d) Water handling system. For pool irradiators, the licensee shall verify that the design of the water purification system is
adequate to meet the requirements of § 36.33(e). The system must be designed so that water leaking from the system does
not drain to unrestricted areas without being monitored.
(e) Radiation monitors. For all irradiators, the licensee shall evaluate the location and sensitivity of the monitor to detect
sources carried by the product conveyor system as required by § 36.29(a). The licensee shall verify that the product
conveyor is designed to stop before a source on the product conveyor would cause a radiation overexposure to any person.
For pool irradiators, if the licensee uses radiation monitors to detect contamination under § 36.59(b), the licensee shall
verify that the design of radiation monitoring systems to detect pool contamination includes sensitive detectors located
close to where contamination is likely to concentrate.
(f) Source rack. For pool irradiators, the licensee shall verify that there are no crevices on the source or between the source
and source holder that would promote corrosion on a critical area of the source. For panoramic irradiators, the licensee shall
determine that source rack drops due to loss of power will not damage the source rack and that source rack drops due to
failure of cables (or alternate means of support) will not cause loss of integrity of sealed sources. For panoramic irradiators,
the licensee shall review the design of the mechanism that moves the sources to assure that the likelihood of a stuck source
is low and that, if the rack sticks, a means exists to free it with minimal risk to personnel.
(g) Access control. For panoramic irradiators, the licensee shall verify from the design and logic diagram that the access
control system will meet the requirements of § 36.23.
(h) Fire protection. For panoramic irradiators, the licensee shall verify that the number, location, and spacing of the smoke
and heat detectors are appropriate to detect fires and that the detectors are protected from mechanical and radiation damage.
The licensee shall verify that the design of the fire extinguishing system provides the necessary discharge patterns,
densities, and flow characteristics for complete coverage of the radiation room and that the system is protected from
mechanical and radiation damage.
(i) Source return. For panoramic irradiators, the licensee shall verify that the source rack will automatically return to the
fully shielded position if offsite power is lost for more than 10 seconds.
(j) Seismic. For panoramic irradiators to be built in seismic areas, the licensee shall design the reinforced concrete radiation
shields to retain their integrity in the event of an earthquake by designing to the seismic requirements of an appropriate
source such as American Concrete Institute Standard ACI 318-89, "Building Code Requirements for Reinforced
Concrete," Chapter 21, "Special Provisions for Seismic Design," or local building codes, if current.
(k) Wiring. For panoramic irradiators, the licensee shall verify that electrical wiring and electrical equipment in the
radiation room are selected to minimize failures due to prolonged exposure to radiation.
§ 36.41 Construction monitoring and acceptance testing.
The requirements of this section must be met for irradiators whose construction begins after July 1, 1993. The requirements
must be met prior to loading sources.
(a) Shielding. For panoramic irradiators, the licensee shall monitor the construction of the shielding to verify that its
construction meets design specifications and generally accepted building code requirements for reinforced concrete.
(b) Foundations. For panoramic irradiators, the licensee shall monitor the construction of the foundations to verify that
their construction meets design specifications.
(c) Pool integrity. For pool irradiators, the licensee shall verify that the pool meets design specifications and shall test the
integrity of the pool. The licensee shall verify that outlets and pipes meet the requirements of § 36.33(b).
(d) Water handling system. For pool irradiators, the licensee shall verify that the water purification system, the conductivity
meter, and the water level indicators operate properly.
(e) Radiation monitors. For all irradiators, the licensee shall verify the proper operation of the monitor to detect sources
carried on the product conveyor system and the related alarms and interlocks required by § 36.29(a). For pool irradiators,
the licensee shall verify the proper operation of the radiation monitors and the related alarm if used to meet § 36.59(b). For
underwater irradiators, the licensee shall verify the proper operation of the over-the-pool monitor, alarms, and interlocks
required by § 36.29(b).
(f) Source rack. For panoramic irradiators, the licensee shall test the movement of the source racks for proper operation
prior to source loading; testing must include source rack lowering due to simulated loss of power. For all irradiators with
product conveyor systems, the licensee shall observe and test the operation of the conveyor system to assure that the
requirements in § 36.35 are met for protection of the source rack and the mechanism that moves the rack; testing must
include tests of any limit switches and interlocks used to protect the source rack and mechanism that moves the rack from
moving product carriers.
(g) Access control. For panoramic irradiators, the licensee shall test the completed access control system to assure that it
functions as designed and that all alarms, controls, and interlocks work properly.
(h) Fire protection. For panoramic irradiators, the licensee shall test the ability of the heat and smoke detectors to detect a
fire, to activate alarms, and to cause the source rack to automatically become fully shielded. The licensee shall test the
operability of the fire extinguishing system.
(i) Source return. For panoramic irradiators, the licensee shall demonstrate that the source racks can be returned to their
fully shielded positions without offsite power.
(j) Computer systems. For panoramic irradiators that use a computer system to control the access control system, the
licensee shall verify that the access control system will operate properly if offsite power is lost and shall verify that the
computer has security features that prevent an irradiator operator from commanding the computer to override the access
control system when it is required to be operable.
(k) Wiring. For panoramic irradiators, the licensee shall verify that the electrical wiring and electrical equipment that were
installed meet the design specifications.
Subpart D--Operation of Irradiators
§ 36.51 Training.
(a) Before an individual is permitted to operate an irradiator without a supervisor present, the individual must be instructed
in:
(1) The fundamentals of radiation protection applied to irradiators (including the differences between external radiation and
radioactive contamination, units of radiation dose, NRC dose limits, why large radiation doses must be avoided, how
shielding and access controls prevent large doses, how an irradiator is designed to prevent contamination, the proper use of
survey meters and personnel dosimeters, other radiation safety features of an irradiator, and the basic function of the
irradiator);
(2) The requirements of parts 19 and 36 of NRC regulations that are relevant to the irradiator;
(3) The operation of the irradiator;
(4) Those operating and emergency procedures listed in § 36.53 that the individual is responsible for performing; and
(5) Case histories of accidents or problems involving irradiators.
(b) Before an individual is permitted to operate an irradiator without a supervisor present, the individual shall pass a written
test on the instruction received consisting primarily of questions based on the licensee's operating and emergency
procedures that the individual is responsible for performing and other operations necessary to safely operate the irradiator
without supervision.
(c) Before an individual is permitted to operate an irradiator without a supervisor present, the individual must have received
on-the-job training or simulator training in the use of the irradiator as described in the license application. The individual
shall also demonstrate the ability to perform those portions of the operating and emergency procedures that he or she is to
perform.
(d) The licensee shall conduct safety reviews for irradiator operators at least annually. The licensee shall give each operator
a brief written test on the information. Each safety review must include, to the extent appropriate, each of the following--
(1) Changes in operating and emergency procedures since the last review, if any;
(2) Changes in regulations and license conditions since the last review, if any;
(3) Reports on recent accidents, mistakes, or problems that have occurred at irradiators, if any;
(4) Relevant results of inspections of operator safety performance;
(5) Relevant results of the facility's inspection and maintenance checks; and
(6) A drill to practice an emergency or abnormal event procedure.
(e) The licensee shall evaluate the safety performance of each irradiator operator at least annually to ensure that regulations,
license conditions, and operating and emergency procedures are followed. The licensee shall discuss the results of the
evaluation with the operator and shall instruct the operator on how to correct any mistakes or deficiencies observed.
(f) Individuals who will be permitted unescorted access to the radiation room of the irradiator or the area around the pool of
an underwater irradiator, but who have not received the training required for operators and the radiation safety officer, shall
be instructed and tested in any precautions they should take to avoid radiation exposure, any procedures or parts of
procedures listed in § 36.53 that they are expected to perform or comply with, and their proper response to alarms required
in this part. Tests may be oral.
(g) Individuals who must be prepared to respond to alarms required by §§ 36.23(b), 36.23(i), 36.27(a), 36.29(a), 36.29(b),
and 36.59(b) shall be trained and tested on how to respond. Each individual shall be retested at least once a year. Tests may
be oral.
§ 36.53 Operating and emergency procedures.
(a) The licensee shall have and follow written operating procedures for--
(1) Operation of the irradiator, including entering and leaving the radiation room;
(2) Use of personnel dosimeters;
(3) Surveying the shielding of panoramic irradiators;
(4) Monitoring pool water for contamination while the water is in the pool and before release of pool water to unrestricted
areas;
(5) Leak testing of sources;
(6) Inspection and maintenance checks required by § 36.61;
(7) Loading, unloading, and repositioning sources, if the operations will be performed by the licensee; and
(8) Inspection of movable shielding required by § 36.23(h), if applicable.
(b) The licensee shall have and follow emergency or abnormal event procedures, appropriate for the irradiator type, for--
(1) Sources stuck in the unshielded position;
(2) Personnel overexposures;
(3) A radiation alarm from the product exit portal monitor or pool monitor;
(4) Detection of leaking sources, pool contamination, or alarm caused by contamination of pool water;
(5) A low or high water level indicator, an abnormal water loss, or leakage from the source storage pool;
(6) A prolonged loss of electrical power;
(7) A fire alarm or explosion in the radiation room;
(8) An alarm indicating unauthorized entry into the radiation room, area around pool, or another alarmed area;
(9) Natural phenomena, including an earthquake, a tornado, flooding, or other phenomena as appropriate for the
geographical location of the facility; and
(10) The jamming of automatic conveyor systems.
(c) The licensee may revise operating and emergency procedures without Commission approval only if all of the following
conditions are met:
(1) The revisions do not reduce the safety of the facility,
(2) The revisions are consistent with the outline or summary of procedures submitted with the license application,
(3) The revisions have been reviewed and approved by the radiation safety officer, and
(4) The users or operators are instructed and tested on the revised procedures before they are put into use.
§ 36.57 Radiation surveys.
(a) A radiation survey of the area outside the shielding of the radiation room of a panoramic irradiator must be conducted
with the sources in the exposed position before the facility starts to operate. A radiation survey of the area above the pool of
pool irradiators must be conducted after the sources are loaded but before the facility starts to operate. Additional radiation
surveys of the shielding must be performed at intervals not to exceed 3 years and before resuming operation after addition
of new sources or any modification to the radiation room shielding or structure that might increase dose rates.
(b) If the radiation levels specified in § 36.25 are exceeded, the facility must be modified to comply with the requirements in
§ 36.25.
(c) Portable radiation survey meters must be calibrated at least annually
to an accuracy of ±20 percent for the gamma energy of the sources
in use. The calibration must be done at two points on each scale or, for
digital instruments, at one point per decade over the range that will
be used. Portable radiation survey meters must be of a type that does
not saturate and read zero at high radiation dose rates.
(d) Water from the irradiator pool, other potentially contaminated liquids, and sediments from pool vacuuming must be
monitored for radioactive contamination before release to unrestricted areas. Radioactive concentrations must not exceed
those specified in 10 CFR part 20, Table 2, Column 2 or Table 3 of appendix B, "Annual Limits on Intake (ALIs) and
Derived Air Concentrations (DACs) of Radionuclides for Occupational Exposure; Effluent Concentrations; Concentrations
for Release to Sewerage."
(e) Before releasing resins for unrestricted use, they must be monitored before release in an area with a background level
less than 0.5 microsievert (0.05 millirem) per hour. The resins may be released only if the survey does not detect radiation
levels above background radiation levels. The survey meter used must be capable of detecting radiation levels of 0.5
microsievert (0.05 millirem) per hour.
§ 36.59 Detection of leaking sources.
(a) Each dry-source-storage sealed source must be tested for leakage at intervals not to exceed 6 months using a leak test kit
or method approved by the Commission or an Agreement State. In the absence of a certificate from a transferor that a test
has been made within the 6 months before the transfer, the sealed source may not be used until tested. The test must be
capable of detecting the presence of 200 becquerels (0.005 microcurie) of radioactive material and must be performed by a
person approved by the Commission or an Agreement State to perform the test.
(b) For pool irradiators, sources may not be put into the pool unless the licensee tests the sources for leaks or has a
certificate from a transferor that leak test has been done within the 6 months before the transfer. Water from the pool must
be checked for contamination each day the irradiator operates. The check may be done either by using a radiation monitor
on a pool water circulating system or by analysis of a sample of pool water. If a check for contamination is done by
analysis of a sample of pool water, the results of the analysis must be available within 24 hours. If the licensee uses a
radiation monitor on a pool water circulating system, the detection of above normal radiation levels must activate an alarm.
The alarm set-point must be set as low as practical, but high enough to avoid false alarms. The licensee may reset the alarm
set-point to a higher level if necessary to operate the pool water purification system to clean up contamination in the pool if
specifically provided for in written emergency procedures.
(c) If a leaking source is detected, the licensee shall arrange to remove the leaking source from service and have it
decontaminated, repaired, or disposed of by an NRC or Agreement State licensee that is authorized to perform these
functions. The licensee shall promptly check its personnel, equipment, facilities, and irradiated product for radioactive
contamination. No product may be shipped until the product has been checked and found free of contamination. If a
product has been shipped that may have been inadvertently contaminated, the licensee shall arrange to locate and survey
that product for contamination. If any personnel are found to be contaminated, decontamination must be performed
promptly. If contaminated equipment, facilities, or products are found, the licensee shall arrange to have them
decontaminated or disposed of by an NRC or Agreement State licensee that is authorized to perform these functions. If a
pool is contaminated, the licensee shall arrange to clean the pool until the contamination levels do not exceed the
appropriate concentration in Table 2, Column 2, appendix B to part 20. (See 10 CFR 30.50 for reporting requirements.)
[58 FR 7728, Feb. 9, 1993, as amended at 58 FR 67660, Dec. 22, 1993]
§ 36.61 Inspection and maintenance.
(a) The licensee shall perform inspection and maintenance checks that include, as a minimum, each of the following at the
frequency specified in the license or license application:
(1) Operability of each aspect of the access control system required by § 36.23.
(2) Functioning of the source position indicator required by § 36.31(b).
(3) Operability of the radiation monitor for radioactive contamination in pool water required by § 36.59(b) using a radiation
check source, if applicable.
(4) Operability of the over-pool radiation monitor at underwater irradiators as required by § 36.29(b).
(5) Operability of the product exit monitor required by § 36.29(a).
(6) Operability of the emergency source return control required by § 36.31(c).
(7) Leak-tightness of systems through which pool water circulates (visual inspection).
(8) Operability of the heat and smoke detectors and extinguisher system required by § 36.27 (but without turning
extinguishers on).
(9) Operability of the means of pool water replenishment required by § 36.33(c).
(10) Operability of the indicators of high and low pool water levels required by § 36.33(d).
(11) Operability of the intrusion alarm required by § 36.23(i), if applicable.
(12) Functioning and wear of the system, mechanisms, and cables used to raise and lower sources.
(13) Condition of the barrier to prevent products from hitting the sources or source mechanism as required by § 36.35.
(14) Amount of water added to the pool to determine if the pool is leaking.
(15) Electrical wiring on required safety systems for radiation damage.
(16) Pool water conductivity measurements and analysis as required by § 36.63(b).
(b) Malfunctions and defects found during inspection and maintenance checks must be repaired without undue delay.
§ 36.65 Attendance during operation.
(a) Both an irradiator operator and at least one other individual, who is trained on how to respond and prepared to promptly
render or summon assistance if the access control alarm sounds, shall be present onsite:
(1) Whenever the irradiator is operated using an automatic product conveyor system; and
(2) Whenever the product is moved into or out of the radiation room when the irradiator is operated in a batch mode.
(b) At a panoramic irradiator at which static irradiations (no movement of the product) are occurring, a person who has
received the training on how to respond to alarms described in § 36.51(g) must be onsite.
(c) At an underwater irradiator, an irradiator operator must be present at the facility whenever the product is moved into or
out of the pool. Individuals who move the product into or out of the pool of an underwater irradiator need not be qualified
as irradiator operators; however, they must have received the training described in § 36.51 (f) and (g). Static irradiations
may be performed without a person present at the facility.
§ 36.67 Entering and leaving the radiation room.
(a) Upon first entering the radiation room of a panoramic irradiator after an irradiation, the irradiator operator shall use a
survey meter to determine that the source has returned to its fully shielded position. The operator shall check the
functioning of the survey meter with a radiation check source prior to entry.
(b) Before exiting from and locking the door to the radiation room of a panoramic irradiator prior to a planned irradiation,
the irradiator operator shall:
(1) Visually inspect the entire radiation room to verify that no one else is in it; and
(2) Activate a control in the radiation room that permits the sources to be moved from the shielded position only if the door
to the radiation room is locked within a preset time after setting the control.
(c) During a power failure, the area around the pool of an underwater irradiator may not be entered without using an
operable and calibrated radiation survey meter unless the over-the-pool monitor required by § 36.29(b) is operating with
backup power.
Subpart E--Records
§ 36.81 Records and retention periods.
The licensee shall maintain the following records at the irradiator for the periods specified.
(a) A copy of the license, license conditions, documents incorporated into a license by reference, and amendments thereto until superseded by new documents or until the
Commission terminates the license for documents not superseded.
(b) Records of each individual's training, tests, and safety reviews provided to meet the requirements of § 36.51(a), (b), (c), (d), (f), and (g) until 3 years after the individual
terminates work.
(c) Records of the annual evaluations of the safety performance of irradiator operators required by § 36.51(e) for 3 years after the evaluation.
(d) A copy of the current operating and emergency procedures required by § 36.53 until superseded or the Commission terminates the license. Records of the radiation safety officer's
review and approval of changes in procedures as required by § 36.53(c)(3) retained for 3 years from the date of the change.
(e) Evaluations of personnel dosimeters required by § 36.55 until the Commission terminates the license.
(f) Records of radiation surveys required by § 36.57 for 3 years from the date of the survey.
(g) Records of radiation survey meter calibrations required by § 36.57 and pool water conductivity meter calibrations required by § 36.63(b) until 3 years from the date of calibration.
(h) Records of the results of leak tests required by § 36.59(a) and the results of contamination checks required by § 36.59(b) for 3 years from the date of each test.
(i) Records of inspection and maintenance checks required by § 36.61 for 3 years.
(j) Records of major malfunctions, significant defects, operating difficulties or irregularities, and major operating problems that involve required radiation safety equipment for 3
years after repairs are completed.
(k) Records of the receipt, transfer and disposal, of all licensed sealed sources as required by §§ 30.51 and 30.41.
(l) Records on the design checks required by § 36.39 and the construction control checks as required by § 36.41 until the license is terminated. The records must be signed and dated.
The title or qualification of the person signing must be included.
(m) Records related to decommissioning of the irradiator as required
by § 30.35(g).
[58 FR 7728, Feb. 9, 1993, as amended at 65 FR 63752, Oct. 24, 2000]
§ 36.83 Reports.
(a) In addition to the reporting requirements in other parts of NRC regulations, the licensee shall report the following events
if not reported under other parts of NRC regulations:
(1) Source stuck in an unshielded position.
(2) Any fire or explosion in a radiation room.
(3) Damage to the source racks.
(4) Failure of the cable or drive mechanism used to move the source racks.
(5) Inoperability of the access control system.
(6) Detection of radiation source by the product exit monitor.
(7) Detection of radioactive contamination attributable to licensed radioactive material.
(8) Structural damage to the pool liner or walls.
(9) Abnormal water loss or leakage from the source storage pool.
(10) Pool water conductivity exceeding 100 microsiemens per centimeter.
(b) The report must include a telephone report within 24 hours as described in § 30.50(c)(1), and a written report within 30
days as described in § 30.50(c)(2).
Subpart F--Enforcement
§ 36.91 Violations.
(a) The Commission may obtain an injunction or other court order to prevent a violation of the provisions of--
(1) The Atomic Energy Act of 1954, as amended;
(2) Title II of the Energy Reorganization Act of 1974, as amended; or
(3) A regulation or order issued pursuant to those Acts.
(b) The Commission may obtain a court order for the payment of a civil penalty imposed under section 234 of the Atomic
Energy Act:
(1) For violations of--
(i) Sections 53, 57, 62, 63, 81, 82, 101, 103, 104, 107, or 109 of the Atomic Energy Act of 1954, as amended;
(ii) Section 206 of the Energy Reorganization Act;
(iii) Any rule, regulation, or order issued pursuant to the sections specified in paragraph (b)(1)(i) of this section;
(iv) Any term, condition, or limitation of any license issued under the sections specified in paragraph (b)(1)(i) of this
section.
(2) For any violation for which a license may be revoked under section 186 of the Atomic Energy Act of 1954, as amended.
§ 36.93 Criminal penalties.
(a) Section 223 of the Atomic Energy Act of 1954, as amended, provides for criminal sanctions for willful violation of,
attempted violation of, or conspiracy to violate, any regulation issued under sections 161b, 161i, or 161o of the Act. For
purposes of section 223, all the regulations in part 36 are issued under one or more of sections 161b, 161i, or 161o, except
for the sections listed in paragraph (b) of this section.
(b) The regulations in part 36 that are not issued under sections 161b, 161i, or 161o for the purposes of section 223 are as
follows: §§ 36.1, 36.2, 36.5, 36.8, 36.11, 36.13, 36.17, 36.19, 36.91, and 36.93.